● On the wire
Technology for the finest homes and superyachts.

BMG Surveys challenges rooftop solar structural checks

Questions over roof-loading calculations and assessor competence put structural evidence in focus for owners planning solar retrofits.

By Callum Reid · · 5 min read

Share
Timber roof structure illustrating the building evidence needed for solar roof structural checks
Timber roof structure illustrating the building evidence needed for solar roof structural checks

Key facts

  • 01BMG Surveys is working with MCS on proposed amendments to structural assessment provisions in MIS 3002.
  • 02BMG questions a 0.785kN/m² loading assumption and the use of a 0.75kN/m² imposed loading allowance.
  • 03BMG considers 0.60kN/m² more appropriate for the relevant roof types and design periods.
  • 04BMG says it has assessed over 500,000 roofs and supported more than 3,000 clients.
  • 05Bryan McGrory wants clearer structural competence requirements; no amendment adoption date has been identified.

BMG Surveys is seeking changes to the structural assessment methods used for UK rooftop solar installations, questioning calculation assumptions and how assessor competence is established. Managing director Bryan McGrory says the firm, which has specialised in solar structural assessment since 2011, has raised its concerns directly with MCS and is working with the organisation on proposed amendments.

What happened

The intervention concerns the structural provisions of MIS 3002 and the methods used to judge whether an existing roof can accommodate a solar installation. BMG’s argument is not that rooftop PV should face a blanket additional hurdle, but that simplified assessments must not be mistaken for a sufficiently informed engineering judgement.

McGrory identifies two particular concerns within the calculation methodologies presented in Table 1. One involves a loading assumption of 0.785kN/m², which BMG says it has been unable to substantiate against recognised structural design standards. Another uses an imposed loading allowance of 0.75kN/m²; BMG considers 0.60kN/m² more appropriate for the relevant roof types and design periods.

Those figures describe disputed assumptions within assessment methods, not universal limits on the weight of solar panels. They should not be used by an owner or installer as a standalone test of roof suitability. BMG’s position is that the calculation must reflect the structure being assessed and the basis on which it was designed.

The firm has also been discussing practical approaches with Local Authority Building Control, or LABC, and the National Association of Professional Inspectors and Testers, NAPIT. Those discussions sit alongside its work with MCS; they do not establish that either organisation has endorsed BMG’s preferred calculations or competence requirements.

The background

Retrofitting solar differs fundamentally from designing a new roof around a known installation. The supporting structure already exists, and its age, construction, condition and capacity can vary considerably. A technically attractive PV proposal therefore begins with an unresolved building question: what can this particular roof safely support?

McGrory says requirements concerning existing roof suitability and the competence of those assessing it have been part of MIS 3002 for years. In BMG’s experience, the persistent weakness is inconsistent interpretation and application rather than the absence of any structural obligation. That distinction matters because compliance cannot be demonstrated simply by treating structural assessment as a newly emerging concern.

BMG reports that it has assessed more than 500,000 roofs and supported over 3,000 clients across domestic, commercial and public-sector installations. Those figures establish the breadth of experience behind its intervention, although they are the company’s own account and do not independently validate the technical changes it advocates.

For a substantial private residence, different roof areas may require different treatment. An original house, later extension and detached outbuilding should not automatically be treated as structurally interchangeable merely because they form one solar project. The practical implication is to define precisely which construction each assessment covers, rather than commission a property-wide answer with an unclear scope.

Structural suitability also concerns more than the downward weight of equipment. General engineering considerations include how loads reach the supporting structure and how fixings respond to forces such as wind uplift. This is why panel specifications alone cannot settle the question: the interface between the array and the building needs its own assessment.

What people are saying

McGrory characterises the simplified methods as preliminary screening rather than a substitute for structural verification. His concern is that software can produce an apparently definitive result even when the person supplying the inputs has not correctly identified the roof or understood how it behaves. The reliability of the output consequently depends on more than the calculation engine.

He is not proposing that assessment software be abandoned. Instead, he argues that its operator must understand the structure, recognise the method’s limitations and know when further engineering input is necessary. That position separates useful automation from professional responsibility: a tool can assist a decision without being capable of taking responsibility for it.

On qualifications, McGrory wants MCS to define structural competence more clearly and believes the threshold would probably require an engineering qualification. He also advocates auditing demonstrable competence rather than assuming it follows from access to software. These are proposals from BMG, not newly announced qualification rules for installers.

Professional indemnity insurance and the allocation of structural compliance responsibilities are further areas where he sees a need for clarity. For owners, that raises a concrete procurement question: which appointed party is responsible for the structural conclusion, and does the scope of its professional appointment match the advice being relied upon?

McGrory says the same difficulties arise less often on commercial installations because insurers, landlords and building owners frequently require structural reports as part of funding arrangements. The relevant lesson for residential commissioning is documentary rather than financial: an explicit requirement for evidence can make the structural decision visible before installation proceeds.

What happens next

BMG is working with MCS on proposed amendments, but no adoption date or final revised wording has been identified. Nor is a substantive MCS response to the individual numerical objections available here. It would therefore be premature to describe the disputed assumptions as withdrawn, or BMG’s preferred approach as an agreed replacement.

Owners with projects under way can ask for the assessment basis without waiting for that process to conclude. A useful record should identify the roof examined, the proposed array, the information used, the assessor and any limitations. This makes it possible to distinguish a completed judgement from an early screening result that still requires follow-up.

Where relevant parts of the structure cannot be inspected, the uncertainty should be made explicit. The project team can then determine whether additional access, investigation or specialist advice is needed. A concealed condition is not resolved by leaving it out of the calculation, and the commissioning programme should allow time to address missing evidence.

Design changes deserve similar attention. If the proposed array layout, mounting arrangement or equipment changes after assessment, the responsible professional should confirm whether the earlier conclusion remains applicable. Otherwise, a valid report for one proposal may be carried forward into construction of a materially different installation.

For integrators coordinating solar with batteries, energy management and wider home controls, the structural decision should be a distinct project responsibility. Electrical design and control integration do not themselves establish roof capacity. Naming the structural decision-maker early helps prevent that task from falling between the solar contractor, building team and homeowner’s adviser.

Why this matters

For owners investing in premium residential energy systems, BMG’s intervention puts the quality of the underlying evidence ahead of a simple pass-or-fail result. A solar retrofit should leave a traceable record of what was assessed, by whom and on what assumptions—information that remains useful when the roof needs maintenance, the array is altered or another professional takes responsibility for the property.

Questions answered

+What is BMG Surveys questioning about solar roof checks?

BMG questions loading assumptions in MIS 3002 assessment methods and how structural competence is established. It argues that simplified calculations and software outputs cannot replace an informed judgement about the actual roof.

+What is MIS 3002?

MIS 3002 is a standard containing provisions relevant to solar PV installations, including existing roof suitability and the competence of those assessing it. BMG’s intervention concerns its structural assessment methods.

+Which roof loading figures does BMG dispute?

BMG questions a 0.785kN/m² assumption and a method using a 0.75kN/m² imposed loading allowance. It considers 0.60kN/m² more appropriate for the relevant roof types and design periods. These are not universal panel-weight limits.

+Can software confirm whether a roof is suitable for solar panels?

McGrory says software can assist assessment, but its operator must understand the structure, supply correct information and recognise when further engineering advice is required. A software result alone does not demonstrate structural competence.

+Have MCS solar structural requirements changed?

BMG is working with MCS on proposed amendments. No final revised wording or adoption date has been identified, so the proposals should not be treated as an agreed replacement for existing requirements.

+What should homeowners request before a solar roof installation?

Owners can request a record identifying the roof and array assessed, the information used, the responsible assessor and any limitations. They should also establish whether the conclusion is a completed assessment or preliminary screening requiring further work.